Skip to main content

Mechanical testing suite, department of Engineering Science, University of Oxford

Mechanical Testing

Our mechanical testing suite includes a 50 kN system for in situ electrochemical testing to investigate hydrogen embrittlement, environmentally assisted cracking and corrosion, alongside a 100 kN Instron 68TM100 for ex situ testing of hydrogen-precharged specimens and conventional testing in air. Both systems support tensile, fracture toughness and fatigue testing, with DCPD and clip gauges for crack growth and displacement monitoring.

In-situ electrochemical testing

Capabilities:

  • In situ mechanical testing under electrochemical hydrogen charging in a range of electrolytes at room temperature

  • Tensile, fracture toughness and fatigue testing

  • Crack growth monitoring using direct current potential drop (DCPD)

  • Calibrated 10 kN and 50 kN load cells

  • Controlled loading rates and fatigue loading conditions

  • Post-test fractography and microstructural characterisation using SEM and EBSD

Instron 68TM100 for ex-situ testing

Capabilities:

  • Ideal for ex situ testing of specimens pre-charged with hydrogen by electrochemical or gaseous methods

  • Tensile, fracture toughness and fatigue testing

  • 100 kN load cell

  • Crack opening displacement (COD) gauge calibrated to ASTM E399

  • Crack growth monitoring using direct current potential drop (DCPD)

  • Controlled loading rates and fatigue loading conditions

  • Post-test fractography and microstructural characterisation using SEM and EBSD

Related Publications

W. Li, A. Zafra, L. Armendáriz, Z. Wang, W. Bailey, E. Martínez-Pañeda, S. Afshan. Cryogenic hydrogen embrittlement of 316plus (EN 1.4420) stainless steel at 77 K and 20 K. International Journal of Hydrogen Energy 233 (2026) 154974. https://doi.org/10.1016/j.ijhydene.2026.154974

D.R. Chalfoun, J. Parker, M. Gagliano, E. Martínez-Pañeda. Tailored heat treatments to characterise the fracture resistance of critical weld regions in hydrogen transmission pipelines. International Journal of Hydrogen Energy 192 (2025) 152347. https://doi.org/10.1016/j.ijhydene.2025.152347

Oxford Hydrogen Research Facility · Jenkin Building, Ground Floor (lab 10.09) · Department of Engineering Science, University of Oxford · Enquiries: